HP P840 HDD RAID 5 many strange drive failuresHP SmartArray P400: How to repair failed logical drive?Reusing Raid 5 Drive?reliably and automatically determine connection path of physical position of HDD from /dev/sdX device fileHow to replace failed drive in RAID 5 array in HP DL380 G4 serverQuestions on increasing RAID 5 arrayRaid 10, Logical device are missingHP Code 341 “Physical Drive State: Predictive failure. This physical drive is predicted to fail soon.”HPE 1.92TB SATA 6G Mixed Use SFF SSD very slow compared to SAS HDD HP disksHP drive array “ready for rebuild” (RAID5)Hard Disc Failure or RAID Glitch

What is this type of notehead called?

How do you respond to a colleague from another team when they're wrongly expecting that you'll help them?

Why in book's example is used 言葉(ことば) instead of 言語(げんご)?

MAXDOP Settings for SQL Server 2014

Can the Supreme Court overturn an impeachment?

How should I respond when I lied about my education and the company finds out through background check?

What linear sensor for a keyboard?

Is it possible to use .desktop files to open local pdf files on specific pages with a browser?

Does the Mind Blank spell prevent the target from being frightened?

Using a siddur to Daven from in a seforim store

Should I install hardwood flooring or cabinets first?

How can "mimic phobia" be cured or prevented?

Do Legal Documents Require Signing In Standard Pen Colors?

Would it be legal for a US State to ban exports of a natural resource?

Did arcade monitors have same pixel aspect ratio as TV sets?

Is there a conventional notation or name for the slip angle?

Is it possible to have a strip of cold climate in the middle of a planet?

Why is Arduino resetting while driving motors?

Drawing a topological "handle" with Tikz

On a tidally locked planet, would time be quantized?

Why has "pence" been used in this sentence, not "pences"?

Find last 3 digits of this monster number

Why do IPv6 unique local addresses have to have a /48 prefix?

Can I sign legal documents with a smiley face?



HP P840 HDD RAID 5 many strange drive failures


HP SmartArray P400: How to repair failed logical drive?Reusing Raid 5 Drive?reliably and automatically determine connection path of physical position of HDD from /dev/sdX device fileHow to replace failed drive in RAID 5 array in HP DL380 G4 serverQuestions on increasing RAID 5 arrayRaid 10, Logical device are missingHP Code 341 “Physical Drive State: Predictive failure. This physical drive is predicted to fail soon.”HPE 1.92TB SATA 6G Mixed Use SFF SSD very slow compared to SAS HDD HP disksHP drive array “ready for rebuild” (RAID5)Hard Disc Failure or RAID Glitch













7















I've been using a RAID5 HDD storage (8x6TB) at my HP P840 for like 2 years now and it has always had unusually many drive failures. Everything was good for half a year, but now drives are failing in a strange way.
For example 2 new drives failed a few days after they have been added to the RAID.
I have also already replaced the RAID controller and am using up-to-date firmware on Mainboard and RAID controller.



Also I have tried to use different drives.
Initially there were HGST DeskStar 6TB drives used in that RAID, now I have been replacing them with HGST UltraStar 6TB when replacing failed drives. But the behaviour is the same.



Also it seems (most of) the drives are not really failed, because once I replaced the RAID controller, one failed drive was recognized as OK again and the rebuild started.



My hoster's support says the problem is that I'm actually using RAID5 and I should switch to RAID10 instead. It's hard for me to believe as I've been using RAID5 without problems at other systems (no drive failures in years).



Can anyone give me a hint, what else the culprit could be? Something wrong with the way the RAID controller is configured?



Thank you!



EDIT:

The server is a HP DL180 G9

Reason for drive failure is always "Write retries failed"



 Smart Array P840 in Slot 1 (sn: PDNNF0ARH321GD)


Port Name: 1I

Port Name: 2I

Internal Drive Cage at Port 1I, Box 2, OK

Internal Drive Cage at Port 1I, Box 2, OK

Internal Drive Cage at Port 2I, Box 1, OK
array A (Solid State SATA, Unused Space: 0 MB)


logicaldrive 1 (447.1 GB, RAID 1+0, OK)

physicaldrive 2I:1:1 (port 2I:box 1:bay 1, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, Solid State SATA, 240.0 GB, OK)

array B (SATA, Unused Space: 0 MB)


logicaldrive 2 (38.2 TB, RAID 5, Interim Recovery Mode)

physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:5 (port 1I:box 2:bay 5, SATA, 6001.1 GB, Failed)
physicaldrive 1I:2:6 (port 1I:box 2:bay 6, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:7 (port 1I:box 2:bay 7, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:8 (port 1I:box 2:bay 8, SATA, 6001.1 GB, OK)


Detailed Info:



 Smart Array P840 in Slot 1
Bus Interface: PCI
Slot: 1
Serial Number: PDNNF0ARH321GD
Cache Serial Number: PEYFP0BRH323YZ
RAID 6 (ADG) Status: Enabled
Controller Status: OK
Hardware Revision: B
Firmware Version: 6.60
Rebuild Priority: High
Expand Priority: Medium
Surface Scan Delay: 3 secs
Surface Scan Mode: Idle
Parallel Surface Scan Supported: Yes
Current Parallel Surface Scan Count: 1
Max Parallel Surface Scan Count: 16
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 15 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 10% Read / 90% Write
Drive Write Cache: Enabled
Total Cache Size: 4.0 GB
Total Cache Memory Available: 3.2 GB
No-Battery Write Cache: Enabled
SSD Caching RAID5 WriteBack Enabled: True
SSD Caching Version: 2
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Spare Activation Mode: Activate on physical drive failure (default)
Controller Temperature (C): 51
Cache Module Temperature (C): 38
Number of Ports: 2 Internal only
Encryption: Disabled
Express Local Encryption: False
Driver Name: hpsa
Driver Version: 3.4.16
Driver Supports HP SSD Smart Path: True
PCI Address (Domain:Bus:Device.Function): 0000:06:00.0
Negotiated PCIe Data Rate: PCIe 3.0 x8 (7880 MB/s)
Controller Mode: RAID
Controller Mode Reboot: Not Required
Latency Scheduler Setting: Disabled
Current Power Mode: MaxPerformance
Host Serial Number: CZ270500GM
Sanitize Erase Supported: False
Primary Boot Volume: logicaldrive 1 (600508B1001CE0F9FACF3A1358647115)
Secondary Boot Volume: logicaldrive 1 (600508B1001CE0F9FACF3A1358647115)


Port Name: 1I
Port ID: 0
Port Connection Number: 0
SAS Address: 5001438038AD05A0
Port Location: Internal
Managed Cable Connected: False

Port Name: 2I
Port ID: 1
Port Connection Number: 1
SAS Address: 5001438038AD05A8
Port Location: Internal
Managed Cable Connected: False

Internal Drive Cage at Port 1I, Box 2, OK
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 1I
Box: 2
Location: Internal

Physical Drives
physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SATA, 6001.1 GB, OK)
None attached


Internal Drive Cage at Port 1I, Box 2, OK
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 1I
Box: 2
Location: Internal

Physical Drives
physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SATA, 6001.1 GB, OK)
None attached


Internal Drive Cage at Port 2I, Box 1, OK
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 2I
Box: 1
Location: Internal

Physical Drives
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, Solid State SATA, 240.0 GB, OK)
None attached

Array: A
Interface Type: Solid State SATA
Unused Space: 0 MB (0.0%)
Used Space: 894.2 GB (100.0%)
Status: OK
MultiDomain Status: OK
Array Type: Data
HP SSD Smart Path: disable



Logical Drive: 1
Size: 447.1 GB
Fault Tolerance: 1+0
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 512 KB
Status: OK
MultiDomain Status: OK
Caching: Enabled
Unique Identifier: 600508B1001CE0F9FACF3A1358647115
Disk Name: /dev/sda
Mount Points: / 18.6 GB Partition Number 2
OS Status: LOCKED
Logical Drive Label: 0216D6F9PDNNF0ARH502MC7DFA
Mirror Group 1:
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, Solid State SATA, 240.0 GB, OK)
Mirror Group 2:
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, Solid State SATA, 240.0 GB, OK)
Drive Type: Data
LD Acceleration Method: Controller Cache

physicaldrive 2I:1:1
Port: 2I
Box: 1
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV712004AG240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 31
Maximum Temperature (C): 39
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 2I:1:2
Port: 2I
Box: 1
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV706303CH240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 29
Maximum Temperature (C): 36
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 2I:1:3
Port: 2I
Box: 1
Bay: 3
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV712003V8240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 29
Maximum Temperature (C): 35
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 2I:1:4
Port: 2I
Box: 1
Bay: 4
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV712004GA240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 31
Maximum Temperature (C): 37
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False


Array: B
Interface Type: SATA
Unused Space: 0 MB (0.0%)
Used Space: 43.7 TB (100.0%)
Status: Failed Physical Drive
MultiDomain Status: OK
Array Type: Data
HP SSD Smart Path: disable

Warning: One of the drives on this array have failed or has been removed.




Logical Drive: 2
Size: 38.2 TB
Fault Tolerance: 5
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 1792 KB
Status: Interim Recovery Mode
MultiDomain Status: OK
Caching: Enabled
Parity Initialization Status: Initialization Failed
Unique Identifier: 600508B1001CF94F84873C91FD89B549
Disk Name: /dev/sdb
Mount Points: None
Logical Drive Label: 04DA1DD6PDNNF0ARH502MC546F
Drive Type: Data
LD Acceleration Method: Controller Cache

physicaldrive 1I:2:1
Port: 1I
Box: 2
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNW7JH
Serial Number: NAHN3UZY
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 37
Maximum Temperature (C): 43
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:2
Port: 1I
Box: 2
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNT517
Serial Number: NAHLKP0X
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 37
Maximum Temperature (C): 56
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:3
Port: 1I
Box: 2
Bay: 3
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: T7MH
Serial Number: NCH8E81Z
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 33
Maximum Temperature (C): 41
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:4
Port: 1I
Box: 2
Bay: 4
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNW7JH
Serial Number: NAHYMAUY
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 34
Maximum Temperature (C): 41
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:5
Port: 1I
Box: 2
Bay: 5
Status: Failed
Last Failure Reason: Write retries failed
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: T7MH
Serial Number: K1H942MD
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Maximum Temperature (C): 43
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Applicable
Sanitize Erase Supported: False

physicaldrive 1I:2:6
Port: 1I
Box: 2
Bay: 6
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: TDR2
Serial Number: K8JM5TKN
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 33
Maximum Temperature (C): 38
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:7
Port: 1I
Box: 2
Bay: 7
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNW7JH
Serial Number: K8H9BW2N
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 34
Maximum Temperature (C): 39
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:8
Port: 1I
Box: 2
Bay: 8
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: T7MH
Serial Number: K1H623JD
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 35
Maximum Temperature (C): 40
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False









share|improve this question



















  • 1





    One of the drives reports 56C maybe that’s a thermal problem? All your drives seem 4K, so I guess the stripes would be correctly aligned.

    – eckes
    Mar 17 at 16:16















7















I've been using a RAID5 HDD storage (8x6TB) at my HP P840 for like 2 years now and it has always had unusually many drive failures. Everything was good for half a year, but now drives are failing in a strange way.
For example 2 new drives failed a few days after they have been added to the RAID.
I have also already replaced the RAID controller and am using up-to-date firmware on Mainboard and RAID controller.



Also I have tried to use different drives.
Initially there were HGST DeskStar 6TB drives used in that RAID, now I have been replacing them with HGST UltraStar 6TB when replacing failed drives. But the behaviour is the same.



Also it seems (most of) the drives are not really failed, because once I replaced the RAID controller, one failed drive was recognized as OK again and the rebuild started.



My hoster's support says the problem is that I'm actually using RAID5 and I should switch to RAID10 instead. It's hard for me to believe as I've been using RAID5 without problems at other systems (no drive failures in years).



Can anyone give me a hint, what else the culprit could be? Something wrong with the way the RAID controller is configured?



Thank you!



EDIT:

The server is a HP DL180 G9

Reason for drive failure is always "Write retries failed"



 Smart Array P840 in Slot 1 (sn: PDNNF0ARH321GD)


Port Name: 1I

Port Name: 2I

Internal Drive Cage at Port 1I, Box 2, OK

Internal Drive Cage at Port 1I, Box 2, OK

Internal Drive Cage at Port 2I, Box 1, OK
array A (Solid State SATA, Unused Space: 0 MB)


logicaldrive 1 (447.1 GB, RAID 1+0, OK)

physicaldrive 2I:1:1 (port 2I:box 1:bay 1, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, Solid State SATA, 240.0 GB, OK)

array B (SATA, Unused Space: 0 MB)


logicaldrive 2 (38.2 TB, RAID 5, Interim Recovery Mode)

physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:5 (port 1I:box 2:bay 5, SATA, 6001.1 GB, Failed)
physicaldrive 1I:2:6 (port 1I:box 2:bay 6, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:7 (port 1I:box 2:bay 7, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:8 (port 1I:box 2:bay 8, SATA, 6001.1 GB, OK)


Detailed Info:



 Smart Array P840 in Slot 1
Bus Interface: PCI
Slot: 1
Serial Number: PDNNF0ARH321GD
Cache Serial Number: PEYFP0BRH323YZ
RAID 6 (ADG) Status: Enabled
Controller Status: OK
Hardware Revision: B
Firmware Version: 6.60
Rebuild Priority: High
Expand Priority: Medium
Surface Scan Delay: 3 secs
Surface Scan Mode: Idle
Parallel Surface Scan Supported: Yes
Current Parallel Surface Scan Count: 1
Max Parallel Surface Scan Count: 16
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 15 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 10% Read / 90% Write
Drive Write Cache: Enabled
Total Cache Size: 4.0 GB
Total Cache Memory Available: 3.2 GB
No-Battery Write Cache: Enabled
SSD Caching RAID5 WriteBack Enabled: True
SSD Caching Version: 2
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Spare Activation Mode: Activate on physical drive failure (default)
Controller Temperature (C): 51
Cache Module Temperature (C): 38
Number of Ports: 2 Internal only
Encryption: Disabled
Express Local Encryption: False
Driver Name: hpsa
Driver Version: 3.4.16
Driver Supports HP SSD Smart Path: True
PCI Address (Domain:Bus:Device.Function): 0000:06:00.0
Negotiated PCIe Data Rate: PCIe 3.0 x8 (7880 MB/s)
Controller Mode: RAID
Controller Mode Reboot: Not Required
Latency Scheduler Setting: Disabled
Current Power Mode: MaxPerformance
Host Serial Number: CZ270500GM
Sanitize Erase Supported: False
Primary Boot Volume: logicaldrive 1 (600508B1001CE0F9FACF3A1358647115)
Secondary Boot Volume: logicaldrive 1 (600508B1001CE0F9FACF3A1358647115)


Port Name: 1I
Port ID: 0
Port Connection Number: 0
SAS Address: 5001438038AD05A0
Port Location: Internal
Managed Cable Connected: False

Port Name: 2I
Port ID: 1
Port Connection Number: 1
SAS Address: 5001438038AD05A8
Port Location: Internal
Managed Cable Connected: False

Internal Drive Cage at Port 1I, Box 2, OK
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 1I
Box: 2
Location: Internal

Physical Drives
physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SATA, 6001.1 GB, OK)
None attached


Internal Drive Cage at Port 1I, Box 2, OK
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 1I
Box: 2
Location: Internal

Physical Drives
physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SATA, 6001.1 GB, OK)
None attached


Internal Drive Cage at Port 2I, Box 1, OK
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 2I
Box: 1
Location: Internal

Physical Drives
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, Solid State SATA, 240.0 GB, OK)
None attached

Array: A
Interface Type: Solid State SATA
Unused Space: 0 MB (0.0%)
Used Space: 894.2 GB (100.0%)
Status: OK
MultiDomain Status: OK
Array Type: Data
HP SSD Smart Path: disable



Logical Drive: 1
Size: 447.1 GB
Fault Tolerance: 1+0
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 512 KB
Status: OK
MultiDomain Status: OK
Caching: Enabled
Unique Identifier: 600508B1001CE0F9FACF3A1358647115
Disk Name: /dev/sda
Mount Points: / 18.6 GB Partition Number 2
OS Status: LOCKED
Logical Drive Label: 0216D6F9PDNNF0ARH502MC7DFA
Mirror Group 1:
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, Solid State SATA, 240.0 GB, OK)
Mirror Group 2:
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, Solid State SATA, 240.0 GB, OK)
Drive Type: Data
LD Acceleration Method: Controller Cache

physicaldrive 2I:1:1
Port: 2I
Box: 1
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV712004AG240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 31
Maximum Temperature (C): 39
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 2I:1:2
Port: 2I
Box: 1
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV706303CH240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 29
Maximum Temperature (C): 36
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 2I:1:3
Port: 2I
Box: 1
Bay: 3
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV712003V8240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 29
Maximum Temperature (C): 35
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 2I:1:4
Port: 2I
Box: 1
Bay: 4
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV712004GA240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 31
Maximum Temperature (C): 37
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False


Array: B
Interface Type: SATA
Unused Space: 0 MB (0.0%)
Used Space: 43.7 TB (100.0%)
Status: Failed Physical Drive
MultiDomain Status: OK
Array Type: Data
HP SSD Smart Path: disable

Warning: One of the drives on this array have failed or has been removed.




Logical Drive: 2
Size: 38.2 TB
Fault Tolerance: 5
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 1792 KB
Status: Interim Recovery Mode
MultiDomain Status: OK
Caching: Enabled
Parity Initialization Status: Initialization Failed
Unique Identifier: 600508B1001CF94F84873C91FD89B549
Disk Name: /dev/sdb
Mount Points: None
Logical Drive Label: 04DA1DD6PDNNF0ARH502MC546F
Drive Type: Data
LD Acceleration Method: Controller Cache

physicaldrive 1I:2:1
Port: 1I
Box: 2
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNW7JH
Serial Number: NAHN3UZY
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 37
Maximum Temperature (C): 43
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:2
Port: 1I
Box: 2
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNT517
Serial Number: NAHLKP0X
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 37
Maximum Temperature (C): 56
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:3
Port: 1I
Box: 2
Bay: 3
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: T7MH
Serial Number: NCH8E81Z
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 33
Maximum Temperature (C): 41
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:4
Port: 1I
Box: 2
Bay: 4
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNW7JH
Serial Number: NAHYMAUY
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 34
Maximum Temperature (C): 41
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:5
Port: 1I
Box: 2
Bay: 5
Status: Failed
Last Failure Reason: Write retries failed
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: T7MH
Serial Number: K1H942MD
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Maximum Temperature (C): 43
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Applicable
Sanitize Erase Supported: False

physicaldrive 1I:2:6
Port: 1I
Box: 2
Bay: 6
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: TDR2
Serial Number: K8JM5TKN
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 33
Maximum Temperature (C): 38
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:7
Port: 1I
Box: 2
Bay: 7
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNW7JH
Serial Number: K8H9BW2N
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 34
Maximum Temperature (C): 39
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:8
Port: 1I
Box: 2
Bay: 8
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: T7MH
Serial Number: K1H623JD
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 35
Maximum Temperature (C): 40
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False









share|improve this question



















  • 1





    One of the drives reports 56C maybe that’s a thermal problem? All your drives seem 4K, so I guess the stripes would be correctly aligned.

    – eckes
    Mar 17 at 16:16













7












7








7








I've been using a RAID5 HDD storage (8x6TB) at my HP P840 for like 2 years now and it has always had unusually many drive failures. Everything was good for half a year, but now drives are failing in a strange way.
For example 2 new drives failed a few days after they have been added to the RAID.
I have also already replaced the RAID controller and am using up-to-date firmware on Mainboard and RAID controller.



Also I have tried to use different drives.
Initially there were HGST DeskStar 6TB drives used in that RAID, now I have been replacing them with HGST UltraStar 6TB when replacing failed drives. But the behaviour is the same.



Also it seems (most of) the drives are not really failed, because once I replaced the RAID controller, one failed drive was recognized as OK again and the rebuild started.



My hoster's support says the problem is that I'm actually using RAID5 and I should switch to RAID10 instead. It's hard for me to believe as I've been using RAID5 without problems at other systems (no drive failures in years).



Can anyone give me a hint, what else the culprit could be? Something wrong with the way the RAID controller is configured?



Thank you!



EDIT:

The server is a HP DL180 G9

Reason for drive failure is always "Write retries failed"



 Smart Array P840 in Slot 1 (sn: PDNNF0ARH321GD)


Port Name: 1I

Port Name: 2I

Internal Drive Cage at Port 1I, Box 2, OK

Internal Drive Cage at Port 1I, Box 2, OK

Internal Drive Cage at Port 2I, Box 1, OK
array A (Solid State SATA, Unused Space: 0 MB)


logicaldrive 1 (447.1 GB, RAID 1+0, OK)

physicaldrive 2I:1:1 (port 2I:box 1:bay 1, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, Solid State SATA, 240.0 GB, OK)

array B (SATA, Unused Space: 0 MB)


logicaldrive 2 (38.2 TB, RAID 5, Interim Recovery Mode)

physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:5 (port 1I:box 2:bay 5, SATA, 6001.1 GB, Failed)
physicaldrive 1I:2:6 (port 1I:box 2:bay 6, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:7 (port 1I:box 2:bay 7, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:8 (port 1I:box 2:bay 8, SATA, 6001.1 GB, OK)


Detailed Info:



 Smart Array P840 in Slot 1
Bus Interface: PCI
Slot: 1
Serial Number: PDNNF0ARH321GD
Cache Serial Number: PEYFP0BRH323YZ
RAID 6 (ADG) Status: Enabled
Controller Status: OK
Hardware Revision: B
Firmware Version: 6.60
Rebuild Priority: High
Expand Priority: Medium
Surface Scan Delay: 3 secs
Surface Scan Mode: Idle
Parallel Surface Scan Supported: Yes
Current Parallel Surface Scan Count: 1
Max Parallel Surface Scan Count: 16
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 15 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 10% Read / 90% Write
Drive Write Cache: Enabled
Total Cache Size: 4.0 GB
Total Cache Memory Available: 3.2 GB
No-Battery Write Cache: Enabled
SSD Caching RAID5 WriteBack Enabled: True
SSD Caching Version: 2
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Spare Activation Mode: Activate on physical drive failure (default)
Controller Temperature (C): 51
Cache Module Temperature (C): 38
Number of Ports: 2 Internal only
Encryption: Disabled
Express Local Encryption: False
Driver Name: hpsa
Driver Version: 3.4.16
Driver Supports HP SSD Smart Path: True
PCI Address (Domain:Bus:Device.Function): 0000:06:00.0
Negotiated PCIe Data Rate: PCIe 3.0 x8 (7880 MB/s)
Controller Mode: RAID
Controller Mode Reboot: Not Required
Latency Scheduler Setting: Disabled
Current Power Mode: MaxPerformance
Host Serial Number: CZ270500GM
Sanitize Erase Supported: False
Primary Boot Volume: logicaldrive 1 (600508B1001CE0F9FACF3A1358647115)
Secondary Boot Volume: logicaldrive 1 (600508B1001CE0F9FACF3A1358647115)


Port Name: 1I
Port ID: 0
Port Connection Number: 0
SAS Address: 5001438038AD05A0
Port Location: Internal
Managed Cable Connected: False

Port Name: 2I
Port ID: 1
Port Connection Number: 1
SAS Address: 5001438038AD05A8
Port Location: Internal
Managed Cable Connected: False

Internal Drive Cage at Port 1I, Box 2, OK
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 1I
Box: 2
Location: Internal

Physical Drives
physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SATA, 6001.1 GB, OK)
None attached


Internal Drive Cage at Port 1I, Box 2, OK
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 1I
Box: 2
Location: Internal

Physical Drives
physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SATA, 6001.1 GB, OK)
None attached


Internal Drive Cage at Port 2I, Box 1, OK
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 2I
Box: 1
Location: Internal

Physical Drives
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, Solid State SATA, 240.0 GB, OK)
None attached

Array: A
Interface Type: Solid State SATA
Unused Space: 0 MB (0.0%)
Used Space: 894.2 GB (100.0%)
Status: OK
MultiDomain Status: OK
Array Type: Data
HP SSD Smart Path: disable



Logical Drive: 1
Size: 447.1 GB
Fault Tolerance: 1+0
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 512 KB
Status: OK
MultiDomain Status: OK
Caching: Enabled
Unique Identifier: 600508B1001CE0F9FACF3A1358647115
Disk Name: /dev/sda
Mount Points: / 18.6 GB Partition Number 2
OS Status: LOCKED
Logical Drive Label: 0216D6F9PDNNF0ARH502MC7DFA
Mirror Group 1:
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, Solid State SATA, 240.0 GB, OK)
Mirror Group 2:
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, Solid State SATA, 240.0 GB, OK)
Drive Type: Data
LD Acceleration Method: Controller Cache

physicaldrive 2I:1:1
Port: 2I
Box: 1
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV712004AG240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 31
Maximum Temperature (C): 39
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 2I:1:2
Port: 2I
Box: 1
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV706303CH240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 29
Maximum Temperature (C): 36
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 2I:1:3
Port: 2I
Box: 1
Bay: 3
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV712003V8240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 29
Maximum Temperature (C): 35
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 2I:1:4
Port: 2I
Box: 1
Bay: 4
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV712004GA240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 31
Maximum Temperature (C): 37
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False


Array: B
Interface Type: SATA
Unused Space: 0 MB (0.0%)
Used Space: 43.7 TB (100.0%)
Status: Failed Physical Drive
MultiDomain Status: OK
Array Type: Data
HP SSD Smart Path: disable

Warning: One of the drives on this array have failed or has been removed.




Logical Drive: 2
Size: 38.2 TB
Fault Tolerance: 5
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 1792 KB
Status: Interim Recovery Mode
MultiDomain Status: OK
Caching: Enabled
Parity Initialization Status: Initialization Failed
Unique Identifier: 600508B1001CF94F84873C91FD89B549
Disk Name: /dev/sdb
Mount Points: None
Logical Drive Label: 04DA1DD6PDNNF0ARH502MC546F
Drive Type: Data
LD Acceleration Method: Controller Cache

physicaldrive 1I:2:1
Port: 1I
Box: 2
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNW7JH
Serial Number: NAHN3UZY
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 37
Maximum Temperature (C): 43
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:2
Port: 1I
Box: 2
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNT517
Serial Number: NAHLKP0X
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 37
Maximum Temperature (C): 56
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:3
Port: 1I
Box: 2
Bay: 3
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: T7MH
Serial Number: NCH8E81Z
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 33
Maximum Temperature (C): 41
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:4
Port: 1I
Box: 2
Bay: 4
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNW7JH
Serial Number: NAHYMAUY
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 34
Maximum Temperature (C): 41
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:5
Port: 1I
Box: 2
Bay: 5
Status: Failed
Last Failure Reason: Write retries failed
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: T7MH
Serial Number: K1H942MD
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Maximum Temperature (C): 43
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Applicable
Sanitize Erase Supported: False

physicaldrive 1I:2:6
Port: 1I
Box: 2
Bay: 6
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: TDR2
Serial Number: K8JM5TKN
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 33
Maximum Temperature (C): 38
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:7
Port: 1I
Box: 2
Bay: 7
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNW7JH
Serial Number: K8H9BW2N
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 34
Maximum Temperature (C): 39
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:8
Port: 1I
Box: 2
Bay: 8
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: T7MH
Serial Number: K1H623JD
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 35
Maximum Temperature (C): 40
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False









share|improve this question
















I've been using a RAID5 HDD storage (8x6TB) at my HP P840 for like 2 years now and it has always had unusually many drive failures. Everything was good for half a year, but now drives are failing in a strange way.
For example 2 new drives failed a few days after they have been added to the RAID.
I have also already replaced the RAID controller and am using up-to-date firmware on Mainboard and RAID controller.



Also I have tried to use different drives.
Initially there were HGST DeskStar 6TB drives used in that RAID, now I have been replacing them with HGST UltraStar 6TB when replacing failed drives. But the behaviour is the same.



Also it seems (most of) the drives are not really failed, because once I replaced the RAID controller, one failed drive was recognized as OK again and the rebuild started.



My hoster's support says the problem is that I'm actually using RAID5 and I should switch to RAID10 instead. It's hard for me to believe as I've been using RAID5 without problems at other systems (no drive failures in years).



Can anyone give me a hint, what else the culprit could be? Something wrong with the way the RAID controller is configured?



Thank you!



EDIT:

The server is a HP DL180 G9

Reason for drive failure is always "Write retries failed"



 Smart Array P840 in Slot 1 (sn: PDNNF0ARH321GD)


Port Name: 1I

Port Name: 2I

Internal Drive Cage at Port 1I, Box 2, OK

Internal Drive Cage at Port 1I, Box 2, OK

Internal Drive Cage at Port 2I, Box 1, OK
array A (Solid State SATA, Unused Space: 0 MB)


logicaldrive 1 (447.1 GB, RAID 1+0, OK)

physicaldrive 2I:1:1 (port 2I:box 1:bay 1, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, Solid State SATA, 240.0 GB, OK)

array B (SATA, Unused Space: 0 MB)


logicaldrive 2 (38.2 TB, RAID 5, Interim Recovery Mode)

physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:5 (port 1I:box 2:bay 5, SATA, 6001.1 GB, Failed)
physicaldrive 1I:2:6 (port 1I:box 2:bay 6, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:7 (port 1I:box 2:bay 7, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:8 (port 1I:box 2:bay 8, SATA, 6001.1 GB, OK)


Detailed Info:



 Smart Array P840 in Slot 1
Bus Interface: PCI
Slot: 1
Serial Number: PDNNF0ARH321GD
Cache Serial Number: PEYFP0BRH323YZ
RAID 6 (ADG) Status: Enabled
Controller Status: OK
Hardware Revision: B
Firmware Version: 6.60
Rebuild Priority: High
Expand Priority: Medium
Surface Scan Delay: 3 secs
Surface Scan Mode: Idle
Parallel Surface Scan Supported: Yes
Current Parallel Surface Scan Count: 1
Max Parallel Surface Scan Count: 16
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 15 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 10% Read / 90% Write
Drive Write Cache: Enabled
Total Cache Size: 4.0 GB
Total Cache Memory Available: 3.2 GB
No-Battery Write Cache: Enabled
SSD Caching RAID5 WriteBack Enabled: True
SSD Caching Version: 2
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Spare Activation Mode: Activate on physical drive failure (default)
Controller Temperature (C): 51
Cache Module Temperature (C): 38
Number of Ports: 2 Internal only
Encryption: Disabled
Express Local Encryption: False
Driver Name: hpsa
Driver Version: 3.4.16
Driver Supports HP SSD Smart Path: True
PCI Address (Domain:Bus:Device.Function): 0000:06:00.0
Negotiated PCIe Data Rate: PCIe 3.0 x8 (7880 MB/s)
Controller Mode: RAID
Controller Mode Reboot: Not Required
Latency Scheduler Setting: Disabled
Current Power Mode: MaxPerformance
Host Serial Number: CZ270500GM
Sanitize Erase Supported: False
Primary Boot Volume: logicaldrive 1 (600508B1001CE0F9FACF3A1358647115)
Secondary Boot Volume: logicaldrive 1 (600508B1001CE0F9FACF3A1358647115)


Port Name: 1I
Port ID: 0
Port Connection Number: 0
SAS Address: 5001438038AD05A0
Port Location: Internal
Managed Cable Connected: False

Port Name: 2I
Port ID: 1
Port Connection Number: 1
SAS Address: 5001438038AD05A8
Port Location: Internal
Managed Cable Connected: False

Internal Drive Cage at Port 1I, Box 2, OK
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 1I
Box: 2
Location: Internal

Physical Drives
physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SATA, 6001.1 GB, OK)
None attached


Internal Drive Cage at Port 1I, Box 2, OK
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 1I
Box: 2
Location: Internal

Physical Drives
physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SATA, 6001.1 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SATA, 6001.1 GB, OK)
None attached


Internal Drive Cage at Port 2I, Box 1, OK
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 2I
Box: 1
Location: Internal

Physical Drives
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, Solid State SATA, 240.0 GB, OK)
None attached

Array: A
Interface Type: Solid State SATA
Unused Space: 0 MB (0.0%)
Used Space: 894.2 GB (100.0%)
Status: OK
MultiDomain Status: OK
Array Type: Data
HP SSD Smart Path: disable



Logical Drive: 1
Size: 447.1 GB
Fault Tolerance: 1+0
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 512 KB
Status: OK
MultiDomain Status: OK
Caching: Enabled
Unique Identifier: 600508B1001CE0F9FACF3A1358647115
Disk Name: /dev/sda
Mount Points: / 18.6 GB Partition Number 2
OS Status: LOCKED
Logical Drive Label: 0216D6F9PDNNF0ARH502MC7DFA
Mirror Group 1:
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, Solid State SATA, 240.0 GB, OK)
Mirror Group 2:
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, Solid State SATA, 240.0 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, Solid State SATA, 240.0 GB, OK)
Drive Type: Data
LD Acceleration Method: Controller Cache

physicaldrive 2I:1:1
Port: 2I
Box: 1
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV712004AG240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 31
Maximum Temperature (C): 39
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 2I:1:2
Port: 2I
Box: 1
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV706303CH240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 29
Maximum Temperature (C): 36
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 2I:1:3
Port: 2I
Box: 1
Bay: 3
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV712003V8240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 29
Maximum Temperature (C): 35
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 2I:1:4
Port: 2I
Box: 1
Bay: 4
Status: OK
Drive Type: Data Drive
Interface Type: Solid State SATA
Size: 240.0 GB
Drive exposed to OS: False
Native Block Size: 4096
Firmware Revision: N2010101
Serial Number: PHDV712004GA240AGN
Model: ATA INTEL SSDSC2BB24
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 31
Maximum Temperature (C): 37
SSD Smart Trip Wearout: Not Supported
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False


Array: B
Interface Type: SATA
Unused Space: 0 MB (0.0%)
Used Space: 43.7 TB (100.0%)
Status: Failed Physical Drive
MultiDomain Status: OK
Array Type: Data
HP SSD Smart Path: disable

Warning: One of the drives on this array have failed or has been removed.




Logical Drive: 2
Size: 38.2 TB
Fault Tolerance: 5
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 1792 KB
Status: Interim Recovery Mode
MultiDomain Status: OK
Caching: Enabled
Parity Initialization Status: Initialization Failed
Unique Identifier: 600508B1001CF94F84873C91FD89B549
Disk Name: /dev/sdb
Mount Points: None
Logical Drive Label: 04DA1DD6PDNNF0ARH502MC546F
Drive Type: Data
LD Acceleration Method: Controller Cache

physicaldrive 1I:2:1
Port: 1I
Box: 2
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNW7JH
Serial Number: NAHN3UZY
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 37
Maximum Temperature (C): 43
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:2
Port: 1I
Box: 2
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNT517
Serial Number: NAHLKP0X
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 37
Maximum Temperature (C): 56
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:3
Port: 1I
Box: 2
Bay: 3
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: T7MH
Serial Number: NCH8E81Z
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 33
Maximum Temperature (C): 41
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:4
Port: 1I
Box: 2
Bay: 4
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNW7JH
Serial Number: NAHYMAUY
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 34
Maximum Temperature (C): 41
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:5
Port: 1I
Box: 2
Bay: 5
Status: Failed
Last Failure Reason: Write retries failed
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: T7MH
Serial Number: K1H942MD
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Maximum Temperature (C): 43
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Applicable
Sanitize Erase Supported: False

physicaldrive 1I:2:6
Port: 1I
Box: 2
Bay: 6
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: TDR2
Serial Number: K8JM5TKN
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 33
Maximum Temperature (C): 38
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:7
Port: 1I
Box: 2
Bay: 7
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: APGNW7JH
Serial Number: K8H9BW2N
Model: ATA HGST HDN726060AL
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 34
Maximum Temperature (C): 39
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False

physicaldrive 1I:2:8
Port: 1I
Box: 2
Bay: 8
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 6001.1 GB
Drive exposed to OS: False
Native Block Size: 4096
Rotational Speed: 7200
Firmware Revision: T7MH
Serial Number: K1H623JD
Model: ATA HUS726060ALE610
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 35
Maximum Temperature (C): 40
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: Not Authenticated. Smart Array will not control drive LEDs.
Sanitize Erase Supported: False






raid raid5 hp-smart-array drive-failure raid-controller






share|improve this question















share|improve this question













share|improve this question




share|improve this question








edited Mar 17 at 14:36







Laord

















asked Mar 17 at 9:03









LaordLaord

434




434







  • 1





    One of the drives reports 56C maybe that’s a thermal problem? All your drives seem 4K, so I guess the stripes would be correctly aligned.

    – eckes
    Mar 17 at 16:16












  • 1





    One of the drives reports 56C maybe that’s a thermal problem? All your drives seem 4K, so I guess the stripes would be correctly aligned.

    – eckes
    Mar 17 at 16:16







1




1





One of the drives reports 56C maybe that’s a thermal problem? All your drives seem 4K, so I guess the stripes would be correctly aligned.

– eckes
Mar 17 at 16:16





One of the drives reports 56C maybe that’s a thermal problem? All your drives seem 4K, so I guess the stripes would be correctly aligned.

– eckes
Mar 17 at 16:16










2 Answers
2






active

oldest

votes


















9














You probably have an heavily punctured array, which cause an early "planned death" of the replaced due to failed stripe reconstruction. You can read more information here and here



The solution is to backup, destroy the array, recreate it and restore from backup.



Next time avoid using a RAID5 array with such big drives. I strongly suggest using RAID6 or, even better, RAID10.






share|improve this answer






























    5














    You should be using RAID6 with the size and types of disks in the system. However, some details about the server may be helpful.



    Is this an HPE server, or are you just using an HPE controller?



    These don't appear to be HPE drives or HPE drive carriers. That's a bad sign.



    The hpssacli output you've provided would also show the reason for the disk failure. If you're not on an HPE server and there's a backplane issue or SATA timeouts (noticed you're on SATA disks), there's chance that you're getting false positives.



    Example: (see the Last Failure Reason line):



     physicaldrive 2I:2:8
    Port: 2I
    Box: 2
    Bay: 8
    Status: Failed
    Last Failure Reason: Aborted Command
    Drive Type: Data Drive





    share|improve this answer























    • Thanks for your answer. The server is a HP DL180 G9; Reason for drive failure is always "Write retries failed". I have added this info to my question.

      – Laord
      Mar 17 at 14:37











    • Why aren't you using HP disks on this system? Are these genuine HP drive carriers?

      – ewwhite
      Mar 17 at 14:47











    • This is rented hardware. I'm using these drives because they are the ones the hoster is offering. Actually i cannot find any info on whether these drives are somewhat certified for HP.

      – Laord
      Mar 17 at 14:59






    • 1





      They are not certified. Your hosting provider is using cheap consumer disks.

      – ewwhite
      Mar 17 at 15:03










    Your Answer








    StackExchange.ready(function()
    var channelOptions =
    tags: "".split(" "),
    id: "2"
    ;
    initTagRenderer("".split(" "), "".split(" "), channelOptions);

    StackExchange.using("externalEditor", function()
    // Have to fire editor after snippets, if snippets enabled
    if (StackExchange.settings.snippets.snippetsEnabled)
    StackExchange.using("snippets", function()
    createEditor();
    );

    else
    createEditor();

    );

    function createEditor()
    StackExchange.prepareEditor(
    heartbeatType: 'answer',
    autoActivateHeartbeat: false,
    convertImagesToLinks: true,
    noModals: true,
    showLowRepImageUploadWarning: true,
    reputationToPostImages: 10,
    bindNavPrevention: true,
    postfix: "",
    imageUploader:
    brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
    contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
    allowUrls: true
    ,
    onDemand: true,
    discardSelector: ".discard-answer"
    ,immediatelyShowMarkdownHelp:true
    );



    );













    draft saved

    draft discarded


















    StackExchange.ready(
    function ()
    StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fserverfault.com%2fquestions%2f958650%2fhp-p840-hdd-raid-5-many-strange-drive-failures%23new-answer', 'question_page');

    );

    Post as a guest















    Required, but never shown

























    2 Answers
    2






    active

    oldest

    votes








    2 Answers
    2






    active

    oldest

    votes









    active

    oldest

    votes






    active

    oldest

    votes









    9














    You probably have an heavily punctured array, which cause an early "planned death" of the replaced due to failed stripe reconstruction. You can read more information here and here



    The solution is to backup, destroy the array, recreate it and restore from backup.



    Next time avoid using a RAID5 array with such big drives. I strongly suggest using RAID6 or, even better, RAID10.






    share|improve this answer



























      9














      You probably have an heavily punctured array, which cause an early "planned death" of the replaced due to failed stripe reconstruction. You can read more information here and here



      The solution is to backup, destroy the array, recreate it and restore from backup.



      Next time avoid using a RAID5 array with such big drives. I strongly suggest using RAID6 or, even better, RAID10.






      share|improve this answer

























        9












        9








        9







        You probably have an heavily punctured array, which cause an early "planned death" of the replaced due to failed stripe reconstruction. You can read more information here and here



        The solution is to backup, destroy the array, recreate it and restore from backup.



        Next time avoid using a RAID5 array with such big drives. I strongly suggest using RAID6 or, even better, RAID10.






        share|improve this answer













        You probably have an heavily punctured array, which cause an early "planned death" of the replaced due to failed stripe reconstruction. You can read more information here and here



        The solution is to backup, destroy the array, recreate it and restore from backup.



        Next time avoid using a RAID5 array with such big drives. I strongly suggest using RAID6 or, even better, RAID10.







        share|improve this answer












        share|improve this answer



        share|improve this answer










        answered Mar 17 at 9:55









        shodanshokshodanshok

        26.6k34787




        26.6k34787























            5














            You should be using RAID6 with the size and types of disks in the system. However, some details about the server may be helpful.



            Is this an HPE server, or are you just using an HPE controller?



            These don't appear to be HPE drives or HPE drive carriers. That's a bad sign.



            The hpssacli output you've provided would also show the reason for the disk failure. If you're not on an HPE server and there's a backplane issue or SATA timeouts (noticed you're on SATA disks), there's chance that you're getting false positives.



            Example: (see the Last Failure Reason line):



             physicaldrive 2I:2:8
            Port: 2I
            Box: 2
            Bay: 8
            Status: Failed
            Last Failure Reason: Aborted Command
            Drive Type: Data Drive





            share|improve this answer























            • Thanks for your answer. The server is a HP DL180 G9; Reason for drive failure is always "Write retries failed". I have added this info to my question.

              – Laord
              Mar 17 at 14:37











            • Why aren't you using HP disks on this system? Are these genuine HP drive carriers?

              – ewwhite
              Mar 17 at 14:47











            • This is rented hardware. I'm using these drives because they are the ones the hoster is offering. Actually i cannot find any info on whether these drives are somewhat certified for HP.

              – Laord
              Mar 17 at 14:59






            • 1





              They are not certified. Your hosting provider is using cheap consumer disks.

              – ewwhite
              Mar 17 at 15:03















            5














            You should be using RAID6 with the size and types of disks in the system. However, some details about the server may be helpful.



            Is this an HPE server, or are you just using an HPE controller?



            These don't appear to be HPE drives or HPE drive carriers. That's a bad sign.



            The hpssacli output you've provided would also show the reason for the disk failure. If you're not on an HPE server and there's a backplane issue or SATA timeouts (noticed you're on SATA disks), there's chance that you're getting false positives.



            Example: (see the Last Failure Reason line):



             physicaldrive 2I:2:8
            Port: 2I
            Box: 2
            Bay: 8
            Status: Failed
            Last Failure Reason: Aborted Command
            Drive Type: Data Drive





            share|improve this answer























            • Thanks for your answer. The server is a HP DL180 G9; Reason for drive failure is always "Write retries failed". I have added this info to my question.

              – Laord
              Mar 17 at 14:37











            • Why aren't you using HP disks on this system? Are these genuine HP drive carriers?

              – ewwhite
              Mar 17 at 14:47











            • This is rented hardware. I'm using these drives because they are the ones the hoster is offering. Actually i cannot find any info on whether these drives are somewhat certified for HP.

              – Laord
              Mar 17 at 14:59






            • 1





              They are not certified. Your hosting provider is using cheap consumer disks.

              – ewwhite
              Mar 17 at 15:03













            5












            5








            5







            You should be using RAID6 with the size and types of disks in the system. However, some details about the server may be helpful.



            Is this an HPE server, or are you just using an HPE controller?



            These don't appear to be HPE drives or HPE drive carriers. That's a bad sign.



            The hpssacli output you've provided would also show the reason for the disk failure. If you're not on an HPE server and there's a backplane issue or SATA timeouts (noticed you're on SATA disks), there's chance that you're getting false positives.



            Example: (see the Last Failure Reason line):



             physicaldrive 2I:2:8
            Port: 2I
            Box: 2
            Bay: 8
            Status: Failed
            Last Failure Reason: Aborted Command
            Drive Type: Data Drive





            share|improve this answer













            You should be using RAID6 with the size and types of disks in the system. However, some details about the server may be helpful.



            Is this an HPE server, or are you just using an HPE controller?



            These don't appear to be HPE drives or HPE drive carriers. That's a bad sign.



            The hpssacli output you've provided would also show the reason for the disk failure. If you're not on an HPE server and there's a backplane issue or SATA timeouts (noticed you're on SATA disks), there's chance that you're getting false positives.



            Example: (see the Last Failure Reason line):



             physicaldrive 2I:2:8
            Port: 2I
            Box: 2
            Bay: 8
            Status: Failed
            Last Failure Reason: Aborted Command
            Drive Type: Data Drive






            share|improve this answer












            share|improve this answer



            share|improve this answer










            answered Mar 17 at 13:11









            ewwhiteewwhite

            174k75368721




            174k75368721












            • Thanks for your answer. The server is a HP DL180 G9; Reason for drive failure is always "Write retries failed". I have added this info to my question.

              – Laord
              Mar 17 at 14:37











            • Why aren't you using HP disks on this system? Are these genuine HP drive carriers?

              – ewwhite
              Mar 17 at 14:47











            • This is rented hardware. I'm using these drives because they are the ones the hoster is offering. Actually i cannot find any info on whether these drives are somewhat certified for HP.

              – Laord
              Mar 17 at 14:59






            • 1





              They are not certified. Your hosting provider is using cheap consumer disks.

              – ewwhite
              Mar 17 at 15:03

















            • Thanks for your answer. The server is a HP DL180 G9; Reason for drive failure is always "Write retries failed". I have added this info to my question.

              – Laord
              Mar 17 at 14:37











            • Why aren't you using HP disks on this system? Are these genuine HP drive carriers?

              – ewwhite
              Mar 17 at 14:47











            • This is rented hardware. I'm using these drives because they are the ones the hoster is offering. Actually i cannot find any info on whether these drives are somewhat certified for HP.

              – Laord
              Mar 17 at 14:59






            • 1





              They are not certified. Your hosting provider is using cheap consumer disks.

              – ewwhite
              Mar 17 at 15:03
















            Thanks for your answer. The server is a HP DL180 G9; Reason for drive failure is always "Write retries failed". I have added this info to my question.

            – Laord
            Mar 17 at 14:37





            Thanks for your answer. The server is a HP DL180 G9; Reason for drive failure is always "Write retries failed". I have added this info to my question.

            – Laord
            Mar 17 at 14:37













            Why aren't you using HP disks on this system? Are these genuine HP drive carriers?

            – ewwhite
            Mar 17 at 14:47





            Why aren't you using HP disks on this system? Are these genuine HP drive carriers?

            – ewwhite
            Mar 17 at 14:47













            This is rented hardware. I'm using these drives because they are the ones the hoster is offering. Actually i cannot find any info on whether these drives are somewhat certified for HP.

            – Laord
            Mar 17 at 14:59





            This is rented hardware. I'm using these drives because they are the ones the hoster is offering. Actually i cannot find any info on whether these drives are somewhat certified for HP.

            – Laord
            Mar 17 at 14:59




            1




            1





            They are not certified. Your hosting provider is using cheap consumer disks.

            – ewwhite
            Mar 17 at 15:03





            They are not certified. Your hosting provider is using cheap consumer disks.

            – ewwhite
            Mar 17 at 15:03

















            draft saved

            draft discarded
















































            Thanks for contributing an answer to Server Fault!


            • Please be sure to answer the question. Provide details and share your research!

            But avoid


            • Asking for help, clarification, or responding to other answers.

            • Making statements based on opinion; back them up with references or personal experience.

            To learn more, see our tips on writing great answers.




            draft saved


            draft discarded














            StackExchange.ready(
            function ()
            StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fserverfault.com%2fquestions%2f958650%2fhp-p840-hdd-raid-5-many-strange-drive-failures%23new-answer', 'question_page');

            );

            Post as a guest















            Required, but never shown





















































            Required, but never shown














            Required, but never shown












            Required, but never shown







            Required, but never shown

































            Required, but never shown














            Required, but never shown












            Required, but never shown







            Required, but never shown







            Popular posts from this blog

            Masuk log Menu navigasi

            Identifying “long and narrow” polygons in with PostGISlength and width of polygonWhy postgis st_overlaps reports Qgis' “avoid intersections” generated polygon as overlapping with others?Adjusting polygons to boundary and filling holesDrawing polygons with fixed area?How to remove spikes in Polygons with PostGISDeleting sliver polygons after difference operation in QGIS?Snapping boundaries in PostGISSplit polygon into parts adding attributes based on underlying polygon in QGISSplitting overlap between polygons and assign to nearest polygon using PostGIS?Expanding polygons and clipping at midpoint?Removing Intersection of Buffers in Same Layers

            Старые Смолеговицы Содержание История | География | Демография | Достопримечательности | Примечания | НавигацияHGЯOLHGЯOL41 206 832 01641 606 406 141Административно-территориальное деление Ленинградской области«Переписная оброчная книга Водской пятины 1500 года», С. 793«Карта Ингерманландии: Ивангорода, Яма, Копорья, Нотеборга», по материалам 1676 г.«Генеральная карта провинции Ингерманландии» Э. Белинга и А. Андерсина, 1704 г., составлена по материалам 1678 г.«Географический чертёж над Ижорскою землей со своими городами» Адриана Шонбека 1705 г.Новая и достоверная всей Ингерманландии ланткарта. Грав. А. Ростовцев. СПб., 1727 г.Топографическая карта Санкт-Петербургской губернии. 5-и верстка. Шуберт. 1834 г.Описание Санкт-Петербургской губернии по уездам и станамСпецкарта западной части России Ф. Ф. Шуберта. 1844 г.Алфавитный список селений по уездам и станам С.-Петербургской губернииСписки населённых мест Российской Империи, составленные и издаваемые центральным статистическим комитетом министерства внутренних дел. XXXVII. Санкт-Петербургская губерния. По состоянию на 1862 год. СПб. 1864. С. 203Материалы по статистике народного хозяйства в С.-Петербургской губернии. Вып. IX. Частновладельческое хозяйство в Ямбургском уезде. СПб, 1888, С. 146, С. 2, 7, 54Положение о гербе муниципального образования Курское сельское поселениеСправочник истории административно-территориального деления Ленинградской области.Топографическая карта Ленинградской области, квадрат О-35-23-В (Хотыницы), 1930 г.АрхивированоАдминистративно-территориальное деление Ленинградской области. — Л., 1933, С. 27, 198АрхивированоАдминистративно-экономический справочник по Ленинградской области. — Л., 1936, с. 219АрхивированоАдминистративно-территориальное деление Ленинградской области. — Л., 1966, с. 175АрхивированоАдминистративно-территориальное деление Ленинградской области. — Лениздат, 1973, С. 180АрхивированоАдминистративно-территориальное деление Ленинградской области. — Лениздат, 1990, ISBN 5-289-00612-5, С. 38АрхивированоАдминистративно-территориальное деление Ленинградской области. — СПб., 2007, с. 60АрхивированоКоряков Юрий База данных «Этно-языковой состав населённых пунктов России». Ленинградская область.Административно-территориальное деление Ленинградской области. — СПб, 1997, ISBN 5-86153-055-6, С. 41АрхивированоКультовый комплекс Старые Смолеговицы // Электронная энциклопедия ЭрмитажаПроблемы выявления, изучения и сохранения культовых комплексов с каменными крестами: по материалам работ 2016-2017 гг. в Ленинградской области